How tankless water heaters work, what a conversion demands from the gas line, venting and electrical supply, and why hard water makes descaling a scheduled job.

A tankless unit heats water as it passes through a heat exchanger, so there is no stored hot water, no standby loss and no tank to rust from the inside. Those are real advantages, and they come with real requirements the building has to meet.

How it changes the gas question

A tank unit fires at a modest input and stores the result. A tankless unit has to raise the water temperature at the moment of demand, which means a much higher input, often several times the tank's. The gas line has to carry that, and the meter and service have to allow it.

This is the most common reason a conversion costs more than expected. An undersized gas line produces a unit that derates, throws an error, or delivers lukewarm water at high flow, and fixing it after the fact means opening walls.

Venting is a different category

Tankless units typically use Category III or IV venting: stainless or polypropylene, with their own clearances and, in condensing models, a condensate drain that has to go somewhere with a slope and a neutralisation path where required. The old tank's flue cannot usually be reused, and a sidewall termination has clearance rules of its own.

Demand and temperature rise

Sizing is a flow question, not a house-size question. A unit is rated for a temperature rise at a flow rate; in winter the incoming water is colder, so the same unit delivers less hot water. Two showers running at once is the case that separates an adequate unit from an impressive spec sheet.

Where the demand is genuinely high, the answer is often two units, staged, rather than one larger unit, which also gives some redundancy when one needs service.

Hard water is the maintenance schedule

San Gabriel Valley Water Company's 2025 report lists hardness averaging 234 ppm, with samples to 280 ppm. In a tank, that hardness settles as sediment. In a tankless unit, it coats the heat exchanger, and the exchanger is the expensive part.

Descaling, which means circulating a mild acid through the unit, is the maintenance that keeps the exchanger alive, and on very hard water it belongs on a schedule rather than on a reaction to a fault code. Many units also have an inlet filter that has to be cleaned more often than the manual's default suggests.

What else changes

A tankless unit needs power for its controls and fan, which means a circuit; it may need a condensate path; and it may need clearances from a window, a door or a neighbouring property line at the vent termination. In a garage, the same ignition-source elevation rule applies.

When tankless is the right answer

Where space is genuinely tight, where hot water demand is concentrated rather than simultaneous, or where the building already has the gas capacity. It is a poor fit where the gas service is marginal, where the water is very hard and nobody will maintain the unit, or where the household wants the lowest installed cost.

When it is not

A conversion that needs a gas service upgrade, a new vent through a finished wall and an electrical circuit can cost several times a straight tank replacement. That is not a reason to refuse it. It is a reason to price it before the decision rather than after.

Tankless Water Heater service areas

How coverage is decided

Get in touch

Considering a tankless conversion?

The gas line, the vent and the water hardness decide whether tankless makes sense. Those three questions are worth asking before the unit is bought.

Questions about this service

Does a tankless unit really last longer than a tank?

The heat exchanger is not sitting in a tank of corrosive water, which removes one failure mode. What replaces it is scale: on very hard water, an exchanger that is never descaled can fail sooner than a tank would, which is why maintenance is the deciding factor.

Can a tankless unit serve a whole house?

Yes, if it is sized for the simultaneous demand and the incoming water temperature. In colder months the same unit delivers less hot water at the same flow, so a unit sized on summer performance can fall short in winter.