When a tank fails in Pomona, the replacement runs through the city's building department and, since January 2026, the 2025 code editions. What decides the price and the schedule is not the tank but everything attached to it.
Deciding it is over
Water under the tank or rust on the jacket means the shell has failed. A bulge means it is failing now. In each case the vessel has lost its pressure boundary, and no field repair restores it.
The other ending is arithmetic. A tank that has been repaired repeatedly in a short span, on a water supply that leaves scale behind, is spending money without buying years. That comparison is worth making while the unit still works.
What a same-spot swap involves
Isolate the water and the fuel, empty the tank, free the water lines, the vent and the gas or electrical connection, take the old unit out, set the new one, reconnect, strap it, fill it, and confirm the relief discharge runs clear.
The parts that surprise people are the peripherals: a corroded shut-off that will not close, a union that will not break free, a vent connector rusted at the collar, a platform that will not hold the new unit's weight, or a closet where the new unit's height does not clear the flue.
Where the scope grows
A larger tank needs the base, the space and the flue to suit it. A change of type pulls in gas sizing, a new vent category and often a circuit. A change of fuel rebuilds the supply side. A change of location rewrites the vent and the relief path and stops being counter work.
Each of those is a legitimate choice, and each should be priced before the unit is ordered rather than after it is delivered.
The permit and the fee
Pomona requires a permit for installation and replacement, issued by the Development Services Department's building division. Fees are set by council resolution under Government Code §§ 66016 and 66020, which is why nobody should quote a figure from an old schedule; the current one is checked at the time.
The inspection that follows is the point of the permit: strapping, venting and cap, relief valve discharge, gas piping with a sediment trap, access and clearances.
After the install
The new tank meets the same water as the old one. Where the supply is hard, scale is the enemy and flushing is the remedy, with an anode rod replaced when spent. That pair of habits is what separates a tank that reaches its rated life from one that does not — and no unit is sold with either.
If the old tank is leaking now
Close the cold valve on top of the tank, or the main. Protect what sits below an upstairs unit. Then call with the size and location so the replacement and its permit can be arranged together.